Thermal performance

Calculating Thermal Bridging

Understand and calculate thermal bridging in aircrete wall construction. Explore guidance and resources to help assess heat loss at junctions and support accurate, energy-efficient building design.

Understanding Thermal Bridging

Thermal bridging occurs at junctions in the building envelope where heat can pass through more readily, increasing heat loss and reducing overall energy efficiency. As buildings become better insulated, these junctions account for an increasingly significant proportion of fabric heat loss.

Accurately calculating thermal bridging is therefore important for SAP assessments, Part L compliance and overall building performance. H+H provides a comprehensive library of calculated Ψ-values for aircrete constructions, developed in accordance with BR 497 to help designers and assessors specify efficient, compliant solutions.

Reducing thermal bridging is therefore essential for improving energy efficiency, achieving Part L compliance, and optimising SAP calculations. H+H aircrete blocks help minimise heat loss at critical junctions by providing significantly better thermal performance than denser masonry materials. This can reduce the impact of linear thermal bridges while avoiding the need for complex or costly enhanced detailing.

On this page, you'll find H+H's comprehensive range of calculated Ψ-values, developed in accordance with BR 497, together with guidance and technical resources to support architects, SAP assessors, housebuilders and specifiers in delivering compliant, energy-efficient buildings.

Why Use H+H Calculated Ψ-Values?

Reduce fabric heat loss

Minimise Fabric Heat Loss

Thermal bridges can account for up to 30% of a building's fabric heat loss. As insulation standards improve and U-values reduce, accurately addressing thermal bridging becomes increasingly important for achieving energy performance targets and reducing heat loss at key junctions.

SAP & Compliance

Supporting accurate SAP assessments

Thermal bridge heat losses must be included within SAP calculations using Ψ-values. Using calculated values rather than conservative default assumptions can help provide a more accurate assessment of building performance and support compliance with Approved Document L.

Industry Standards

Calculated to BR497

H+H Ψ-values are developed using recognised industry methodologies and follow the guidance set out in BR497. This provides confidence that calculations are robust, compliant and suitable for use within SAP assessments and energy performance calculations.

Technical Expertise

Built on technical expertise

For more than 16 years, H+H has played an active role in the development of thermal bridge calculations and construction details. Our technical team continues to develop and maintain Ψ-values specifically for H+H aircrete systems, helping designers and assessors achieve compliant, energy-efficient solutions.

Compare Thermal Bridge Performance by Junction

Find calculated Ψ-values for external wall and party wall junctions, organised around SAP Appendix K junction types. Each junction includes values across relevant wall constructions, insulation specifications and H+H products, making it easier to identify an appropriate solution for your project.

Where applicable, you'll also find references to H+H Standard Detail Drawings, helping you connect calculated thermal performance with the corresponding construction detail.

A Complete Resource for Thermal Bridging Calculations

Extensive Coverage

5,300+ Calculated Ψ-Values

H+H has developed a comprehensive library of more than 5,300 calculated Ψ-values covering a wide range of wall, floor and foundation constructions. Values are available for Solar, Standard, High Strength and Super Strength aircrete blocks across multiple build-ups and insulation specifications.

Regulatory Compliance

Developed to Industry Standards

All calculations have been produced in accordance with BR497 conventions and relevant industry guidance, providing SAP assessors and designers with confidence that the values are suitable for use in energy performance calculations and compliance assessments.

Designed for Practical Use

Ready for SAP Assessments

The H+H Calculated Ψ-Values document is designed to support efficient specification and assessment workflows. Values are clearly organised and referenced, making it easy to identify the correct junction details and associated thermal bridge calculations.

Flexible Design Solutions

Suitable for Multiple Wall Types

The calculations cover a broad range of construction options, including partial-fill and full-fill cavity walls, beam and block floors, separating walls and foundation block applications. Typical wall U-values range from approximately 0.11 to 0.30 W/m²K, providing flexibility across a variety of projects.

Site Checklists

Dedicated Site Checklists

Each wall type includes a dedicated checklist designed to support quality assurance and verify that critical thermal bridge details have been constructed as specified.

Easy Download

Share Information with Project Teams

Checklists can be completed electronically or in print and shared between site teams, assessors and project stakeholders to help ensure the final EPC reflects the as-built specification.

Access calculated Ψ-Values and supporting technical resources

5,300+ calculated Ψ-values

BR 497-compliant

SAP-ready references

H+H construction details

Site compliance checklists

FAQs

What is thermal bridging?

Thermal bridging occurs where heat passes more readily through a localised area of the building envelope, such as wall junctions, openings or structural elements. These areas can increase heat loss, reduce energy efficiency and affect a building's overall thermal performance.

Why is thermal bridging important?

As buildings become better insulated, heat loss through junctions accounts for a greater proportion of overall fabric heat loss. Minimising thermal bridging helps improve energy efficiency, supports Part L compliance and contributes to better SAP assessment results.

What is a Ψ-value?

A Ψ-value (Psi-value) measures the heat loss through a linear thermal bridge, such as where walls meet floors, roofs or window openings. It is expressed in W/mK and is used within SAP calculations to assess the impact of junctions on a building's overall thermal performance.

Why should I use calculated Ψ-values instead of default values?

Calculated Ψ-values provide a more accurate representation of a building's construction details than default values. Using calculated values can demonstrate improved thermal performance, reduce calculated fabric heat loss and support compliance with Building Regulations.

How are H+H Ψ-values calculated?

H+H's calculated Ψ-values are developed using recognised calculation methodologies in accordance with BR 497. They are based on H+H aircrete wall constructions and common junction details to provide reliable data for specification and SAP assessments.

Who can use H+H calculated Ψ-values?

H+H calculated Ψ-values are designed for architects, SAP assessors, energy consultants, specifiers, developers, housebuilders and other construction professionals involved in designing and assessing energy-efficient buildings.

Do H+H aircrete blocks help reduce thermal bridging?

Yes. H+H aircrete blocks have excellent thermal performance compared with denser masonry materials, helping to reduce heat loss at junctions and minimise the impact of linear thermal bridges within masonry construction.

Where can I get help selecting the correct Ψ-values?

If you're unsure which calculated Ψ-values are appropriate for your project, the H+H Technical Team can provide guidance on suitable construction details and supporting technical documentation.

Where to next?

Looking for more information?

Design & Build resources

Technical resources

Access technical guidance, CAD drawings, BIM objects, certifications and design tools to support your project.

Find answers to common questions

Frequently asked questions

Browse our FAQs for information on H+H products, technical guidance, ordering and more.